Job Hazard Analysis · HVAC
Job Hazard Analysis: Split system installation
Install a residential or light-commercial split AC or heat pump: set the outdoor condensing unit on a pad or wall bracket, set the indoor air handler or evaporator coil in an attic, closet, or crawlspace, run and braze the copper line set, wire the disconnect and controls, pressure test, evacuate, charge refrigerant, and start up. Attic and roof-side work may involve high heat, ladders, and tight spaces.
Published 2026-10-23
A general example for this task. Your JHA should reflect your crew, equipment and site — review it with a competent person before work starts.
Steps, hazards and controls
| Step | Hazard | Risk | Controls |
|---|---|---|---|
| 1. Unload the condenser, air handler, line set, and cylinders from the truck and move them to the work areas. | Back strain or crushed fingers lifting a 150–250 lb condenser or air handler. | Medium |
|
| Compressed gas cylinders (nitrogen, acetylene, refrigerant) falling or rolling. | High |
| |
| 2. Set the outdoor unit on the pad or wall bracket and drill the wall penetration for the line set. | Hidden wires, gas pipe, or water pipe hit while drilling through the wall. | High |
|
| Silica dust when drilling brick, block, stucco, or concrete. | Medium |
| |
| Falling from a ladder while mounting a wall bracket. | Medium |
| |
| 3. Set the indoor air handler or evaporator coil in the attic, closet, or crawlspace. | Falling through the ceiling drywall between attic joists. | High |
|
| Heat illness in a hot attic. | High |
| |
| Fiberglass insulation irritating skin, eyes, and lungs. | Low |
| |
| Falling from a stepladder at the attic hatch. | Medium |
| |
| 4. Run the copper line set, condensate drain, and control wire between the units. | Cuts from tubing cutters, sheet metal, and sharp copper ends. | Low |
|
| Shock or kickback from a damaged cord or drill binding. | Medium |
| |
| 5. Braze the line set connections with a torch while flowing nitrogen. | Fire from the torch flame igniting wood framing, insulation, or siding. | High |
|
| Burns from the flame and hot copper. | Medium |
| |
| Leaking acetylene or damaged hoses causing fire or explosion. | High |
| |
| Nitrogen or brazing fumes building up in a tight attic or crawlspace, displacing oxygen. | Medium |
| |
| 6. Install the disconnect and whip, and connect power and control wiring. | Electrocution from an energized 240V circuit or panel. | High |
|
| 7. Pressure test with nitrogen, pull a vacuum, and charge refrigerant. | Hose or fitting blowout from overpressure. | High |
|
| Frostbite to hands or eyes from liquid refrigerant. | Medium |
| |
| Refrigerant leak in a closet, basement, or crawlspace reducing oxygen; some newer refrigerants are mildly flammable. | Medium |
| |
| 8. Start up and test the system, then clean up the work areas. | Caught by the condenser fan or blower, or shocked while taking readings. | Medium |
|
| Trips and cuts from scrap copper, sheet metal, boxes, and cords. | Low |
|
Required PPE
- Safety glasses — ANSI Z87.1 at all times; shade 3–5 lenses when brazing.
- Work gloves — Cut-resistant for sheet metal and copper; leather for brazing; insulated for refrigerant hoses.
- Safety-toe boots — When moving and setting equipment.
- Hard hat or bump cap — Hard hat when overhead work or falling objects are present; bump cap in attics and crawlspaces.
- Respirator — N95 for insulation dust; N95 or better for masonry drilling if dust controls are not enough.
- Hearing protection — Earplugs when core drilling or using hammer drills.
- Long sleeves and pants — Cotton or flame-resistant when brazing; covers skin from fiberglass.
Training
- EPA Section 608 certification for anyone handling or charging refrigerant.
- Ladder safety training by a competent person.
- Brazing, torch, and compressed gas cylinder safety, including fire watch.
- Lockout/tagout and electrical safety for working on 240V circuits.
- Heat illness recognition and prevention.
- Hazard communication: reading SDS for refrigerants, nitrogen, acetylene, and PVC cement.
Emergency
If someone is shocked, do not touch them until the power is off at the breaker. Call 911 and give the site address. Start CPR if they are not breathing and use an AED if available. For fire, shut the torch and cylinder valves, use the extinguisher only if small, otherwise get everyone out and call 911.
Official sources
- 29 CFR 1926.1053 — Ladders
- 29 CFR 1926.350 — Gas welding and cutting (cylinders)
- 29 CFR 1926.352 — Fire prevention (welding and cutting)
- 29 CFR 1926.416 — Electrical — general requirements
- 29 CFR 1926.417 — Lockout and tagging of circuits
- 29 CFR 1926.300 — Hand and power tools — general requirements
- 29 CFR 1926.102 — Eye and face protection
- OSHA — Heat — hazard recognition and prevention